Product Details
7622100 ML ACR Charging Relay 12V 500A with Manual Control & Deutsch Connector
500 Amp magnetic latching (bi-stable) relay automatically combines batteries during charging and isolates batteries when discharging and when starting engine.
Features:
- Manual control switch provides an added level of safety allowing control with or without power, and offering LOCK OFF capability for servicing
- Automatically manages the charging of two large battery banks
- Allows paralleling of battery banks for emergency starting
- 500 Ampere continuous rating to support high-output alternators
- Magnetic Latch (ML)—ACR draws very low current (<40mA to monitor terminal voltage) in the "ON" or "OFF" states, and draws moderate current for very short time when changing state
- Dual sensing—senses charge on both battery banks
- Start Isolation (SI)—can be configured for temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronics
- Engine Isolation (EI)—can be configured for isolation of two engines while both are running to protect engine electronics and maximize alternator output
- Senses charging on two battery banks
- LED output to remotely indicate when batteries are combined, isolated, in voltage lockout, or in Start or Engine isolation
- 3/8"-16 tin-plated copper studs for maximum conductivity and corrosion resistance
- 7/8" (22mm) stud length accepts multiple cable terminals
- Silver alloy contacts provide high reliability for switching live loads
- Label recesses for circuit identification
Specifications:
- Control Circuit Connection: Deutsch DTM
- Nominal Voltage: 12VDC
- Manual Control: Yes
- Engine Isolation: Yes
- Mounting: #10
- Start Assist: Yes
- Start Isolation: Yes
- Amperage Operating Current: 13mA
- Amperage Operating Current When Changing State: <7.0A
- Terminal Stud Torque: 140 in-lb (15.82 Nm)
- Continuous Rating: 500A
- Intermittent Rating: 700A (5 min)
- Cranking Rating 30 Seconds: 1450A DC
- Cable Size to Meet Ratings: 2x (4/0)
- Live Current Switching: 300A@12VDC
- Switching Cycles: 100,000
- Terminal Ring Diameter Clearance: 1.18" (29.97 mm)
- Terminal Stud Length: 0.875" (22.23 mm)
- Terminal Stud Size: 3/8" - 16 (M10)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.

![Analytic Systems 200A, 40V 3-Bank Ideal Battery Isolator [IBI3-40-200] - Rough Seas Marine](http://roughseasmarine.com/cdn/shop/products/83579XL_{width}x.jpg?v=1677101985)
![Analytic Systems AC Charger 2-Bank 20A 12V Out, 110VAC In, w/Digital Volt/Amp Meter [BCA310V-110-12] - Rough Seas Marine](http://roughseasmarine.com/cdn/shop/products/77017XL_{width}x.jpg?v=1677099967)
![Analytic Systems AC Charger 2-Bank 70A, 12V Out, 85-264VAC In Power-Factor Correction [BCA1050-12]](http://roughseasmarine.com/cdn/shop/files/104280XL_{width}x.jpg?v=1733505660)
![Analytic Systems AC Intelligent Pure Sine Wave Inverter 1200W, 20-40V In, 110V Out [IPSI1200-20-110] - Rough Seas Marine](http://roughseasmarine.com/cdn/shop/products/77020XL_{width}x.jpg?v=1677099967)
![Analytic Systems AC Power Supply 20/25A, 12V Out, 85-265V In [PWI320-12] - Rough Seas Marine](http://roughseasmarine.com/cdn/shop/products/77022XL_{width}x.jpg?v=1677099974)
![Analytic Systems IBC320-12 Battery Charger [IBC320-12] - Rough Seas Marine](http://roughseasmarine.com/cdn/shop/products/85296XL_{width}x.jpg?v=1677102708)
![Analytic Systems Waterproof IP66 DC Battery Charger 10A, 24V Out, 30-80V In, Ruggedized [BCH10W-24] - Rough Seas Marine](http://roughseasmarine.com/cdn/shop/products/77031XL_{width}x.jpg?v=1677099986)